Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Peik-Rayekan,L.  Seifpanahi-Shabani,K.  Yousefi-Limaee,N.  Sillanpää,M.    
Article title: Development of a magnetic ion-imprinted polymer with selective adsorption performance and solid state colourimetric detection of lead ions
Publication date: 2026
Journal : International Journal of Environmental Analytical Chemistry
Volume: 106
Issue: (8)
Page numbers: (2242-2261)
DOI: 10.1080/03067319.2025.2571748

Abstract: In this research, a novel chemosensor based on magnetic ion-imprinted polymer was developed for the colourimetric detection and selective removal of lead ions. In this regard, magnetic and non-magnetic ion-imprinted polymers were prepared as well as magnetic and non-magnetic non-imprinted polymers. In the magnetic form, Fe3O4@SiO2-NH2 was synthesised and applied as a substrate. Lead (II), sodium rhodisonate, 2-hydroxyethyl methacrylate, sodium formaldehyde sulfoxylate/ethylene glycol dimethacrylate and tert-butyl hydroperoxide were applied to prepare the IIP-based sensor. Fe3O4@SiO2@NIP and related non-magnetic NIP were prepared in the absence of lead ions. The characterisation of chemosensor was carried out using Scanning Electron Microscopy, Thermal Gravimetric Analysis, Fourier Transform Infrared Spectroscopy, Energy Dispersive X-Ray Analysis, and X-Ray Diffraction Analysis. The obtained results indicated the appropriate imprinting factor by comparing the adsorptive capability of Fe3O4@SiO2@IIP (192.308 mg g-1) and Fe3O4@SiO2@NIP (107.527 mg g-1). The adsorption data for both Fe3O4@SiO2@NIP and Fe3O4@SiO2@IIP fitted well to the Langmuir isotherm (R2 ≥ 0.9871) and pseudo-second-order kinetic model (R2 ≥ 0.9998). Also, adsorption selectivity of magnetic IIP and NIP for Pb2+ were determined against interfering ions indicating the proper relative selectivity coefficient for the adsorption of lead ions versus all investigated interfering ions. In addition, colourimetric analyses were performed by evaluating CIE Lab parameters (L*, a*, b*, C* and h°), for the IIP, NIP, the magnetic composite and the extracted samples, demonstrating clear differences that support the successful identification and visible change in the colour of the chemosensor in the exposure of lead ions.
Template and target information:   lead ion; Pb(II)
Author-assigned keywords: Ion-imprinted polymer; colourimetric detection; lead; selective adsorption; chemosensor




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website