Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Geramizadegan,A.  Ghazanfari,D.  Amiri,A.    
Article title: Determination of amount herbicide toxic fenpyroximate in surface water by analysis molecularly imprinted solid phase extraction method and relative error assessment using artificial neural network model
Publication date: 2023
Journal : International Journal of Environmental Analytical Chemistry
Volume: 103
Issue: (20)
Page numbers: (9002-9018)
DOI: 10.1080/03067319.2021.2001465

Abstract: This work describes the development of an analytical methodology to determine toxic fenpyroximate in surface water using molecularly imprinted polymers (MIPs) as the extraction and pre-concentration material, followed by high performance liquid chromatography. A new molecularly imprinted polymer, prepared following a non-covalent approach, was synthesised using toxic fenpyroximate as the template molecule, methacrylic acid as a functional monomer, and ethylene glycol dimethacrylate as a cross-linker. A method for the determination of traces of toxic fenpyroximate was developed using this polymer as the enrichment sorbent coupled with high performance liquid chromatography focusing on surface water samples. The calibration curve was linear in the range of 0.1 to 1.0 µg L-1. The standard deviation is 2.9%, and the detection limit of the method is 0.2 µg L-1 and r2 = 0.9869. The observed outcomes confirmed the suitability recovery and a very low detection limit for measuring toxic fenpyroximate. It was demonstrated that the proposed MI-SPE-HPLC method could be applied for direct determination of toxic fenpyroximate in surface water. The observed outcomes confirmed the suitability of the artificial neural network model as a tool for MSE (mean square error) of fenpyroximate on (MSEANN = 0.41, MSEFL = 0.36 and MSEANFIS = 0.23) selectivity and permeability. It was demonstrated that the proposed MI-SPE-HPLC method could be applied for direct determination of toxic fenpyroximate in surface water.
Template and target information:   fenpyroximate
Author-assigned keywords: Fenpyroximate; molecular imprinting polymer; mean square error; solid phase extraction; trace analysis; neural network model




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website