Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Cui,A.L.  Yang,Z.  Feng,X.W.  Zhao,H.Y.  Meng,P.R.  Xie,Y.X.  Miao,L.N.  Sun,Y.    
Article title: Preparation and properties of hemoglobin (Hb)-imprinted poly (ionic liquid)s via seATRP in only 5 μL Volumes
Publication date: 2022
Journal : Journal of Polymer Research
Volume: 29
Issue: (9)
Article number: 384
DOI: 10.1007/s10965-022-03237-6

Abstract: Hemoglobin (Hb) imprinted poly (ionic liquid)s (HIPILs) were fabricated on the surface of Pt wire modified with nano-gold (nAu) via simplified electrochemically mediated atom transfer radical polymerization (seATRP) in only 5 μL volumes. The micro upgrade seATRP was mainly carried out by two platinum wires electrode. The one platinum wire was bare and applied as the counter electrode, the other one was modified segmentally, which made it could be used both as a catalytic electrode of seATRP and the substrate of HIPILs. The HIPILs were prepared by using Hb as the template, 1-vinyl-3-propyl-imidazole sulfonate (VPIS) ionic liquids and N, N′-methylene bis-acrylamide (MBA) as the functional monomer and cross-linking agent of HIPILs, respectively. When a constant current was applied to the catalytic electrode, Fe (III) in Hb would be reduced to Fe (II), seATRP of VPIS would be triggered on the surface of Pt/nAu electrode. After Hb was removed, the HIPILs modified electrode (Pt/nAu/HIPILs) was obtained. The Pt/nAu/HIPILs electrode was characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). Further experiments indicated that the Pt/nAu/HIPILs electrode could be utilized as electrochemical sensor to determine Hb by differential pulse voltammetry (DPV). The linear response range was 1.0 × 10–12 ~ 1.0 × 10–1 mg/mL and the detection limit was 3.29 × 10–13 mg/mL (S/N = 3). Compared with other Hb sensors based on imprinting polymers, the broader linear range and lower detection limit suggested the promising prospect of the biosensor.
Template and target information:   protein; hemoglobin; Hb
Author-assigned keywords: Imprinted poly (ionic liquid)s; seATRP; 5 μL; Biosensor




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website