Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Li,X.  Li,B.  Huang,J.  Zhu,H.Y.  Li,Y.  Shi,G.    
Article title: A molecular imprinting photoelectrochemical sensor modified by polymer brushes and its detection for BSA
Publication date: 2024
Journal : Chemical Engineering Journal
Volume: 483
Article number: 149297
DOI: 10.1016/j.cej.2024.149297
Alternative URL: https://www.sciencedirect.com/science/article/pii/S1385894724007824

Abstract: Polydopamine (PDA)-based molecular imprinting photoelectrochemical (MIP-PEC) sensor is usually applied to recognize proteins. However, the abundant active functional groups on the PDA surface lead to a non-specific adsorption at the non-imprinted sites, resulting in a decrease in the ability of the MIP-PEC sensor to qualitatively analyze proteins. To solve this problem, in the present work, the polymer brush is specially designed to been grafted onto the PDA imprinted layer of the Si-based photoelectrode and then reduces the probability of non-specific adsorption, improving the specific detection ability. In addition, the Si-based photoelectrode was formed by successively modifying buried junction, nitrogen-doped carbon and TiO2 on the Si wafer with micropyramid structure, enhancing the photocurrent density of the photoelectrode and improving the detection sensitivity. The experimental results suggest that the specific recognition ability of the MIP-PEC sensor to BSA was significantly improved with an increase of imprinting factor from 5.10 to 7.06. Also, the sensing signals showed a good linearity with BSA concentration in a range of 10-16-10-9 mg·mL−1, and a limit of detection of 2.203 × 10-17 mg·mL−1 (S/N = 3). Furthermore, it was also successful to analysis as the template of acetylcholine was used, confirming the universality of this method.
Template and target information:   protein; bovine serum albumin; BSA
Author-assigned keywords: Molecularly imprinted polydopamine; Polymer brushes; MIP-PEC sensor; Specific recognition




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website