Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Xu,S.P.  Mu,F.H.  Wu,W.S.  Tao,L.X.  Pan,C.  Dai,B.L.    
Article title: A Simple and Sensitive Imprinted Electrochemical Sensor for Detection of Bongkrekic Acid in Food
Publication date: 2026
Journal : Electroanalysis
Volume: 38
Issue: (8)
Article number: e70208
DOI: 10.1002/elan.70208

Abstract: Bongkrekic acid (BKA) is a highly toxic chemical substance harmful to humans. In this work, a sensitive, selective, and inexpensive imprinted electrochemical sensor for the determination of BKA was developed. The gold nanoparticles-modified ITO electrode (AuNPs/ITO electrode) increases the specific surface area and conductivity ensuring high sensitivity of the sensor. Subsequently, a molecular-imprinted polymer film (MIP) was prepared on the surface of the AuNPs/ITO electrode through in situ electro-polymerization. The BKA-polydopamine MIP (BKA-PDA-MIP) can specifically recognize BKA ensures the high selectivity of the sensor. The higher the BKA concentration, the more occupation on the MIP/AuNPs/ITO electrode surface, so that leads to the lower electron-transfer rate and the smaller the DPV signal. This imprinted electrochemical sensor exhibited a satisfactory detection range from 1 to 400 ng mL-1 and a low detection limit (LOD) of 0.542 ng mL-1. Furthermore, the proposed sensor was successfully applied to detect BKA in real food samples, indicating a good application prospect in actual sample determination.
Template and target information:   bongkrekic acid; BKA
Author-assigned keywords: bongkrekic acid; electrochemical sensor; gold nanoparticles; molecular imprinted polymer




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website