Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Féo,M.P.C.  Hoppe,T.D.  Brondani,D.    
Article title: Electropolymerized Molecularly Imprinted Poly(L-Phenylalanine) Modified Lab-Made Screen-Printed Carbon Electrode for Voltammetric Analysis of Acetaminophen
Publication date: 2025
Journal : Electroanalysis
Volume: 37
Issue: (5)
Article number: e12047
DOI: 10.1002/elan.12047

Abstract: A selective molecularly imprinted polymer (MIP) sensor was constructed on a lab-made screen-printed carbon electrode (SPCE) for the electrochemical determination of acetaminophen (AP). Different conductive carbon inks have been investigated for SPCE production. The sensor was prepared by direct electropolymerization of the L-phenylalanine on bare SPCE in the presence of the template molecule (AP). Physicochemical and morphological characterization studies of the sensor preparation steps were performed, including scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), conductivity, contact angle, electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Under optimized experimental conditions, the differential pulse voltammetry (DPV) response was linearly proportional to the AP concentration between 0.2 and 100 μmol L-1 with a limit of detection (LOD) of 30 nmol L-1. The MIP sensor showed good analytical performance, selectivity, and stability. Also, it was successfully used to quantify AP in fortified water samples.
Template and target information:   acetaminophen; AP; paracetamol
Author-assigned keywords: acetaminophen; electrochemical sensor; molecularly imprinted polymer; poly(L-phenylalanine); screen-printed carbon electrode




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website