Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Özçelik,H.  Yaşar,E.  Güner,T.  Dokuzparmak,E.  Şarkaya,K.  Akgöl,S.    
Article title: Molecularly Imprinted Nanoparticle-Based Polymer (Acrylamide-N-Vinyl imidazole)/Nafion Film Modified Screen-Printed Electrode System for Rapid Determination of Hemoglobin
Publication date: 2024
Journal : Electroanalysis
Volume: 36
Issue: (12)
Article number: e202400274
DOI: 10.1002/elan.202400274

Abstract: In medical diagnostics, variations in hemoglobin levels can reveal a variety of prevalent health conditions. Abnormal hemoglobin is known to be connected with diseases like anemia, diabetes, hematemesis, hematuria, and hemoglobinuria. Consequently, there is a significant demand for advanced detection technologies and precise methodologies to accurately track and assess hemoglobin levels. This study demonstrates the potential of a novel molecularly imprinted nanoparticle-based sensor system to rapidly analyze hemoglobin levels without the need for a laboratory environment. Hemoglobin imprinted-poly(acrylamide-co-vinyl imidazole) [Hb-imp-p(AAm-co-VIM)] nanoparticles with high affinity and selectivity for hemoglobin were synthesized and loaded onto the surface of a screen-printed carbon electrode (SPCE) with a nafion nanofilm. Nafion has selective ion exchange properties and allows for the enhancement of the electrochemical signal. An increase in signal was observed in the presence of 0.5% Nafion. The Hb-imp-p(AAm-co-VIM)/Nafion-SPCE system was employed as the sensor surface for the detection of hemoglobin levels in blood. The Hb-imp-p(AAm-co-VIM)/Nafion-SPCE system was characterized by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) measurements. The linear working range for hemoglobin was observed to be 0.73-15.54 μM (R2: 0.9934), with a calculated limit of detection (LoD) value of 0.24 μM (3.3 S/N). The sensor system exhibited high efficiency at the biological pH value of 7.4. Furthermore, percent recovery values for hemoglobin in blood samples were observed to be between 90.34% and 103.68%. To determine the selectivity of the Hb-imp-p(AAm-co-VIM)/Nafion-SPCE electrode system, the current values of the system were investigated in the presence of ascorbic acid, cysteine, glucose, and IgG. The system exhibited high selectivity. Based on the data obtained, it is evident that the Hb-imp-p(AAm-co-VIM)/Nafion-SPCE system can detect hemoglobin in biological environments and has the potential for use in disease monitoring systems.
Template and target information:   protein; hemoglobin; Hb
Author-assigned keywords: electrochemical sensor; hemoglobin; molecularly imprinted polymer; nafion




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website