Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Dhara,M.  Banerjee,S.  Ghorai,S.  Das,N.  KumarChakraborty,A.  Bandyopadhyay,R.  Tudu,B.    
Article title: TiO2-Graphite Supported Hybrid MIP Sensor for Sensitive Vitamin C Detection in Cosmetics
Publication date: 2025
Journal : IEEE Sensors Journal
Volume: 25
Issue: (19)
Page numbers: (35757-35764)
DOI: 10.1109/JSEN.2025.3598128
Alternative URL: https://ieeexplore.ieee.org/document/11128958

Abstract: In this study, an ascorbic acid-selective polymer composite—molecularly imprinted poly(4-vinylpyridine) (4-VP) integrated with titanium dioxide nanomaterials on graphite (AA-MI-P(4-VP)@TiO2-G) was synthesized using a hybrid polymerization technique, combining sol-gel and thermal polymerization processes. The material served as a biosensor based on molecular imprinting for the highly sensitive detection of ascorbic acid (AA) via cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The imprinted polymer’s morphology, elemental composition, structure, and imprinting endorsement were investigated by scanning electron microscopy (FESEM), Fourier transform infrared spectroscopy (FTIR), UV-visible spectroscopy (UV-Vis), Brunauer–Emmett–Teller (BET) analysis, and energy-dispersive X-ray spectroscopy (EDX). Electrochemical impedance spectroscopy (EIS) showed that TiO2 modification reduced charge transfer resistance in AA solution, enhancing current sensitivity by approximately 1.5 x compared to the bare molecularly imprinted polymer (MIP) sensor. Under optimized conditions, the DPV peak currents of the biosensor showed a wide linear response over the concentration range of 10–4000 μM with a detection limit of 0.059 μM (S/N =3) and a quantification limit of 0.18 μM. Experimental results demonstrate that the AA-MI-P(4-VP)@TiO2-G biosensor exhibits excellent AA sensing performance, with high repeatability, selectivity, and stability, even in the presence of interfering compounds like dopamine (DA) and uric acid (UA). The proposed biosensor was successfully used for the quantification of AA in cosmetics with the help of a robust statistical model developed by the partial least squares regression (PLSR) technique. The model showed a high prediction of 95.27% for the detection of AA in cosmetic samples. The results were in agreement with those obtained by high-performance liquid chromatography (HPLC).
Template and target information:   ascorbic acid; AA; vitamin C
Author-assigned keywords: Ascorbic acid (AA); electrochemical process; hybrid polymerization; molecular imprinting technique; partial least square regression




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website