Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Gao,Y.W.  Zhang,C.R.  Zhang,L.K.  Kang,Q.  Shen,D.Z.  Zhang,P.    
Article title: A differential strategy to enhance the anti-interference ability of molecularly imprinted photoelectrochemical sensor with semi-logarithmic calibration curve demonstrated by SnS/TiO2 NTs to carbendazim
Publication date: 2026
Journal : Microchemical Journal
Volume: 230
Article number: 119736
DOI: 10.1016/j.microc.2026.119736
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0026265X26029413

Abstract: Carbendazim (CBZ) is a broad-spectrum fungicide but also a potential carcinogen. Herein, a photoelectrochemical (PEC) sensor for CBZ was developed by using SnS modified TiO2 nanotube arrays (TiO2 NTs/Ti) as the photosensitive electrode. After depositing a SnS layer via successive ionic layer adsorption and reaction method, the photocurrent from the resultant SnS/TiO2 NTs/Ti was 6.7-fold and 3.7-fold those from TiO2 NTs/Ti and SnS/ITO (under visible light excitation), respectively. Based on the photocurrent enhancement of SnS/TiO2 NTs/Ti by CBZ, the PEC sensor was used to determine CBZ with a detection limit of 0.14 nM. To improve the selectivity, a molecularly imprinted polymer (MIP) membrane of CBZ were electrochemically polymerized on the surface of SnS/TiO2 NTs/Ti using pyrrole as the functional monomer. The resultant MIP membrane (with an imprinting factor of 5.1) not only improved the selectivity of the PEC sensor, but also enhanced its sensitivity. The photocurrent is in a linear correlation with the logarithmic concentration of CBZ from 0.1 nM to 10 μM, with a detection limit of 0.031 nM. To improve further the anti-interference ability of proposed MIP-PEC sensor, a differential strategy is explored to correct the interference due to the non-specific adsorption on the surface of MIP-PEC sensor with semi-logarithmic calibration curve. The differential PEC signals from interferents were − 9.3% ∼12.6% of those in normal PEC signals. The proposed method was used to determine the residual CBZ in actual samples with complex matrices.
Template and target information:   carbendazim; CBZ
Author-assigned keywords: Photoelectrochemical sensor; Molecular imprinting polymers; Differential strategy; Carbendazim




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website