Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Mostafa,A.M.  Alqahtani,R.A.A.  Mahmoud,A.M.  El-Wekil,M.M.  Ali,A.-M.B.H.  Park,J.P.  Barker,J.    
Article title: Deep eutectic solvent-based molecularly imprinted polymers for selective extraction and HPLC-SEC determination of pepsin in human saliva
Publication date: 2026
Journal : Microchemical Journal
Volume: 230
Article number: 119763
DOI: 10.1016/j.microc.2026.119763
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0026265X26029681

Abstract: Early and non-invasive detection of gastroesophageal reflux disease (GERD) remains challenging, highlighting the need for selective and environmentally sustainable analytical methods for salivary biomarkers. In this study, eco-friendly molecularly imprinted polymers (MIPs) based on deep eutectic solvents (DESs) were developed for the selective extraction of pepsin enzyme from human saliva. Two DES systems were designed: a DES functional monomer composed of methacrylic acid and choline chloride, and a DES comonomer consisting of itaconic acid and [2-(methacryloyloxy)ethyl] trimethylammonium chloride. Surface imprinting polymerization was performed on silica nanoparticles using pepsin as the template, ethylene glycol dimethacrylate (EGDMA) as the crosslinker, and ammonium persulfate as the initiator in phosphate buffer. The resulting DES-MIPs exhibited preferential recognition toward pepsin, achieving a binding capacity (Q) of 385 mg g−1, significantly exceeding that of non-imprinted polymers (NIPs) (205 mg g−1), with negligible interference from other salivary enzymes such as amylase and lipase. Structural and thermal characterization using FT-IR, TGA, DSC, and SEM confirmed the successful formation and stability of the imprinted polymers. Adsorption kinetics followed a pseudo-second-order model (R2 = 0.999), while the adsorption isotherm fitted the Langmuir model (R2 = 0.906), indicating monolayer chemisorption on a homogeneous surface. After extraction, pepsin was eluted with phosphate buffer and quantified by HPLC-SEC. The integrated DES-MIP-HPLC-SEC method showed linearity between 0.5 and 150 μg mL−1 with a limit of detection of 0.15 μg mL−1. The method demonstrated strong green analytical performance, achieving a 0.76 AGREEmip score and 80% GAPI score, confirming its sustainability.
Template and target information:   protein; pepsin
Author-assigned keywords: Molecularly imprinted polymers; Deep eutectic solvents; Pepsin enzyme; Green analysis; Biosensors; Gastroesophageal reflux disease




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website