Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Shao,Y.M.  Rong,X.  Wang,P.  Zhao,H.H.  Feng,H.R.  Ma,W.L.  Peng,W.L.  Gao,G.H.  Yang,X.Y.  Jiao,Z.W.    
Article title: Molecular imprinting ratiometric fluorescence sensor for visual and sensitive detection of tetrabromobisphenol A
Publication date: 2027
Journal : Journal of Photochemistry and Photobiology A: Chemistry
Volume: 483
Article number: 117618
DOI: 10.1016/j.jphotochem.2026.117618
Alternative URL: https://www.sciencedirect.com/science/article/pii/S1010603026005976

Abstract: A molecularly imprinted polymer (MIP) ratiometric fluorescence sensor was prepared for visual and sensitive detection of tetrabromobisphenol A (TBBPA). The sensor was prepared by simply mixing silica-coated blue-fluorescent carbon quantum dots (CQDs@SiO2) as the reference signal and yellow-fluorescent molecularly imprinted polymer with embedded CdTe QDs (y-CdTe@MIP) as the responsive signal. The specific binding of TBBPA to the imprinted cavities of the MIP results in fluorescence quenching of the yellow CdTe QDs at 570 nm. In contrast, the blue fluorescence intensity of the silica-coated CQDs at 440 nm remains unchanged. The detection conditions were optimized and the performance of the ratiometric fluorescence sensor was evaluated through fluorescence experiments. Under optimal conditions, a good linear relationship was established between the fluorescence intensity ratio (I570/I440)0/(I570/I440) of the sensor and the concentration of TBBPA in the range of 0–15 μM, with a detection limit as low as 10.4 nM. Furthermore, a pronounced fluorescence color change from yellow to blue is visible to the naked eye, allowing for the visual detection of TBBPA. Moreover, the sensor can effectively detected TBBPA in water samples, with recoveries ranging from 97.47% to 105.67% and relative standard deviation (RSD) below 4.1%. The results demonstrate that the sensor shows great promise for application in the sensitive and accurate detection of TBBPA in real water samples.
Template and target information:   tetrabromobisphenol A; TBBPA
Author-assigned keywords: Molecularly imprinted polymer; Ratiometric fluorescence sensor; Tetrabromobisphenol A; Quantum dots; Water samples




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website