Mipdatabase live, currently comprising 19188 items



Reference Type: Journal
Authors:   Ren,Y.Y.  Shen,T.Y.  Zhang,L.Y.  Pan,R.  Yang,W.L.  Chen,M.H.    
Article title: Thermoresponsive imprinted fiber sensor for glyphosate detection with nondestructive elution
Publication date: 2026
Journal : Chemical Engineering Journal
Volume: 549
Article number: 182666
DOI: 10.1016/j.cej.2026.182666
Alternative URL: https://www.sciencedirect.com/science/article/pii/S1385894726101296

Abstract: Glyphosate is the most widely used herbicide in the world, and its excessive residues in water and food have become a serious food safety concern. A thermoresponsive molecularly imprinted optical fiber sensor was developed in this study for the non-destructive detection of glyphosate. Through room-temperature photoinitiated polymerization, an Fe3O4@SiO2@P(NIPAM-co-4-VP) sensitive membrane with a “core-shell-shell” structure was functionalized onto the surface of an optical fiber. Poly (N-isopropylacrylamide) acts as a thermal switch, enabling reversible “on-off” control of the imprinted cavities, while 4-vinylpyridine provides specific binding affinity for glyphosate. The lower critical solution temperature of the imprinted membrane is 36.47 °C. The sensor exhibits a maximum wavelength shift of 34.82 nm within a glyphosate concentration range of 0–200 μM, and the equilibrium adsorption data are better described by the Langmuir model than by the Freundlich model within the investigated concentration range. The sensor sensitivity reaches 0.17 nm/μM, with a limit of detection as low as 0.38 μM. The sensor exhibits stable and reversible responses during multiple adsorption-desorption cycles and can be regenerated through temperature control without the use of acidic eluents. This study eliminates the destructive acid elution paradigm, providing a green and reversible platform for pesticide residue monitoring.
Template and target information:   glyphosate
Author-assigned keywords: Optical fiber sensor; Glyphosate detection; Molecularly imprinted polymer; Thermosensitive




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website