Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Zhang,L.  Xiao,X.  Cheng,Z.R.  Hou,X.Y.  Du,H.Z.    
Article title: Nanostructured PEDOT/g-C3N4 Composite-Based Ion-Imprinted Electrochemical Sensor for Sensitive Cd(II) Detection
Publication date: 2026
Journal : ACS Applied Nano Materials
Volume: 9
Issue: (34)
Page numbers: (16444-16456)
DOI: 10.1021/acsanm.6c02668

Abstract: Cadmium (Cd2+), among the most hazardous heavy-metal pollutants, enters ecosystems through both natural processes and anthropogenic activities. This study developed an electrochemical sensor using a two-dimensional nanomaterialcomposite strategy, which synergistically integrates ion-imprinted poly(3,4-ethylenedioxythiophene) (IIP-PEDOT) with graphite carbon nitride (g-C3N4) nanomaterials for ultrasensitive Cd2+ detection. First, the IIP film was fabricated via electropolymerization of EDOT monomers on a g-C3N4-modified screen-printed carbon electrode (SPCE), leveraging hydrophobic interactions and π–π conjugation effects between EDOT molecules and g-C3N4 nanosheets. Subsequently, density functional theory (DFT) simulations elucidated the energy changes of the polymerization-complex structure formed by Cd2+ with functional monomers, while also clarifying the coordination binding mechanisms between metal ions and recognition sites within imprinted cavities. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) were systematically employed to characterize the morphological features and chemical composition of the IIP-PEDOT/g-C3N4 nanocomposite material, validating the uniform dispersion of PEDOT polymer chains on the g-C3N4 nanocarrier and confirming the stability of interfacial interactions. Experimental results demonstrated that the sensor exhibited superior selective Cd2+ recognition capability with a remarkably low detection limit of 75 ng/L (0.67 nM) across a linear range of 0.01–10 μM, substantially outperforming EU drinking-water regulatory thresholds (approximately 45 μM), reflecting the superiority of the sensor. Furthermore, biological validation based on mouse-exposure models confirmed that the sensor could accurately reflect Cd2+ accumulation levels in blood, liver, and kidney tissues. Additionally, the sensor demonstrates outstanding detection capabilities in the human blood environment, suggesting promising clinical biosample analysis applications. In brief, this IIP-PEDOT/g-C3N4 nanocomposite sensing platform offers a cost-effective, rapid, and field-deployable solution for monitoring Cd2+ contamination in environmental and biomedical matrices.
Template and target information:   cadmium ion; Cd(II)
Author-assigned keywords: cadmium ion detection; Ion-imprinted polymer; PEDOT; electrochemical sensor; nanocomposite




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website