Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Wang,T.  Guo,Y.  Dang,X.P.  Guo,L.    
Article title: CoFe-LDH/MWCNTs-based molecularly imprinted electrochemical sensor and machine learning-assisted detection of catechol
Publication date: 2026
Journal : Microchemical Journal
Volume: 230
Article number: 119955
DOI: 10.1016/j.microc.2026.119955
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0026265X26031607

Abstract: For the extremely sensitive and selective detection of catechol (CC), a molecularly imprinted electrochemical sensor composed of a cobalt‑iron layered double hydroxide/multi-walled carbon nanotubes (CoFe-LDH/MWCNTs) composite was fabricated. Here, oxidized MWCNTs served as a conductive scaffold, while the in situ grown CoFe-LDH nanosheets provided fast electron-transfer kinetics and strong enrichment capability through their positively charged layers. SEM, XRD, FT-IR, XPS and BET characterizations confirmed the successful synthesis of a loose, porous CoFe-LDH/MWCNTs nanocomposite. Using CC as the template and pyrrole as the functional monomer, a molecularly imprinted polymer (MIP) film was electropolymerized onto the glassy carbon electrode that had been modified with the composite. This synergistic combination of the conductive, porous CoFe-LDH/MWCNTs scaffold and the MIP film endowed the sensor with both amplified electrochemical signals and specific recognition capability. The sensor exhibited a good linear DPV current response to the concentration of CC, along with outstanding anti-interference performance, reproducibility, repeatability, and short-term storage stability. Notably, a PCA-GPR machine-learning approach was integrated to process the electrochemical impedance spectroscopy (EIS) data, significantly improving prediction accuracy. When applied to real environmental water samples, the sensor achieved recoveries of 97.2%–102.0%, with relative standard deviation (RSD) values below 4.85%. The EIS-PCA-GPR approach achieved low detection limits (LOD = 0.0109 μmol/L; LOQ = 0.0331 μmol/L) and successfully predicted trace CC concentrations as low as 0.0114 μmol/L. This intelligent sensing platform enables rapid, accurate, cost-effective trace-CC detection in aquatic environments, demonstrating the combined merits of composite materials, molecular imprinting and machine learning.
Template and target information:   catechol; CC
Author-assigned keywords: Cobalt‑iron layered double hydroxide; Molecularly imprinted polymer; Electrochemical sensor; Machine learning; Catechol




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website