Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Wang,T.T.  Zhao,F.J.  Suo,Z.G.  Liu,Y.  Huang,Y.W.  Wei,M.    
Article title: Aptamer/magnetic-MIP dual-recognition sandwich biosensor for rapid and recyclable determination of kanamycin in food
Publication date: 2026
Journal : Analytica Chimica Acta
Volume: 1423
Article number: 346165
DOI: 10.1016/j.aca.2026.346165
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0003267026011153

Abstract: Background The rapid and precise monitoring of antibiotic residues is a cornerstone of food safety and diagnostic science. Herein, we report a high-performance dual-recognition sandwich-type fluorescent biosensor engineered by integrating Fe3O4@UiO-66-based molecularly imprinted polymers (FUMIP) with a fluorescein-labeled aptamer probe (Apt-FAM) for the ultrasensitive detection of kanamycin (KANA). Results Central to this design is the confined microenvironment provided by the FUMIP framework, which facilitates the selective pre-concentration of KANA through coordinated boronate affinity and hydrogen bonding. This interfacial enrichment significantly facilitates subsequent recognition by the Apt-FAM probe, forming a stable sandwich architecture that achieves a 156-fold sensitivity enhancement compared with the single-recognition control system constructed in this work. The FUMIP component exhibits a superior imprinting factor of 5.19 and an adsorption capacity of 45.11 mg/g, ensuring high-fidelity target capture even in complex matrices. The optimized biosensor enables rapid quantification within 30 min, delivering an exceptional detection limit of 0.0032 ng/mL across a broad linear range (0.01-1000 ng/mL). In comparison, the single-recognition sensor exhibits a linear range of 1-500 ng/mL with a detection limit of 0.5010 ng/mL. Furthermore, the sensor demonstrates robust reusability (70% signal retention after 20 cycles) and high practical reliability, with recoveries of 98.0%-106.2% in real food samples. Significance This work not only provides an advanced platform for KANA monitoring but also offers a universal strategy for the ultrasensitive detection of small-molecule contaminants by exploiting the synergy between synthetic and biological receptors.
Template and target information:   kanamycin; KANA
Author-assigned keywords: Kanamycin; Molecularly imprinted polymer; Aptamer; Dual-recognition; Fluorescent biosensor




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website