Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Arhami,M.  Asghari,A.  Shahdost-Fard,F.  Moslem,Z.  Rajabi,M.    
Article title: Salivary and urinary monitoring of tramadol by a scalable electrochromic sensor: toward a non-invasive assay with a colorful palette
Publication date: 2026
Journal : Microchemical Journal
Volume: 230
Article number: 119949
DOI: 10.1016/j.microc.2026.119949
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0026265X26031541

Abstract: Tramadol (TRM) misuse and its overdose have become a significant public health concern worldwide. According to World Health Organization (WHO) estimates, in 2019, approximately 25% of the roughly 6 × 105 deaths were due to drug use globally. This study introduces the fabrication of an electrochromic sensor based on an indium tin oxide (ITO) electrode modified with a molecularly imprinted polymer (MIP) and polyaniline (PANI) for the dual-mode detection of TRM. The developed sensor integrated quantitative electrochemical measurement via differential pulse voltammetry (DPV) and visual detection via color changes on the electrochromic platform to demonstrate a low limit of detection (LOD) of 0.333 nM and a wide linear dynamic range (LDR) from 1 to 900 nM, with a calibration equation of ΔI(μA) = 0.0184 [TRM] + 2.4672 (R2 = 0.9945). Furthermore, the visual readout showed a linear R-channel response (y = 0.1585x + 52.2, R2 = 0.9747) over the same concentration range based on (Red, Green, and Blue) RGB analyses. Selectivity of the proposed method was confirmed against several structurally related compounds and potential interferents with good satisfaction. In spiked human saliva and urine samples, recovery values ranged from 99.00% to 101.00% with RSD values below 4%. This novel MIP/PANI/ITO sensor offers a low-cost, scalable, and portable platform for real-time monitoring of TRM, with potential applications in clinical diagnostics and forensic screening.
Template and target information:   tramadol; TRM
Author-assigned keywords: Tramadol; Electrochromic sensor; Polyaniline; Molecularly imprinted polymer; Visual assay




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website