Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Wang,R.  Xue,J.P.  Tan,C.Y.  Jia,B.R.  Zhang,P.  Chen,L.X.  Li,J.H.  Song,Z.H.    
Article title: Rapid analysis of mercury ion in real samples via ion-imprinted nanoparticle-based test strips
Publication date: 2026
Journal : Analytical and Bioanalytical Chemistry
Volume: 418
Issue: (21)
Page numbers: (6877-6889)
DOI: 10.1007/s00216-026-06686-w

Abstract: Mercury ion (Hg2+) contamination poses severe threats to ecological systems and human health, necessitating the development of facile and rapid monitoring methodologies. Herein, a fluorescence sensing system integrating ion-imprinted polymer (IIP) nanoparticle (NP)-based test strips with a miniaturized fluorimeter was fabricated for rapid quantitative analysis of Hg2+ in complicated matrix samples. First, CdTe quantum dot (QD)-coated silica (CdTe@SiO2) NPs and Hg2+-imprinted polymer-functionalized CdTe@SiO2 (Hg-IIPs@CdTe@SiO2) NPs were synthesized via an ion-imprinting strategy using Hg2+ as the template ion via ion-imprinting technology. Critical synthetic parameters, including the feed ratios of functional monomer, cross-linker, and catalyst, as well as the loading volume of QDs, were systematically optimized. Characterizations verified that the as-prepared Hg-IIPs@CdTe@SiO2 NPs displayed regular spherical morphology, desirable component distribution, and favorable fluorescence performance. Further mechanistic investigation revealed that Hg2+ effectively quenched the intrinsic fluorescence of Hg-IIPs@CdTe@SiO2 NPs via a combination of dynamic quenching and Förster resonance energy transfer (FRET). Benefiting from the good fluorescence properties of specific recognition of the system, the constructed sensing platform achieved high sensitivity with a limit of detection (LOD) of 9.1 ng/L, superior anti-interference selectivity, and satisfactory reproducibility and storage stability (relative standard deviation, RSD < 5%). Green Analytical Procedure Index (GAPI) assessment confirmed the eco-friendly feature of the proposed detection strategy. Finally, the developed sensing system was successfully applied for Hg2+ quantification in real samples, highlighting its promising application prospect for environmental supervision, food safety, and pharmaceutical inspection.
Template and target information:   mercury ion; Hg(II)
Author-assigned keywords: Mercury ion; CdTe quantum dots; Ion-imprinted polymers; Fluorescence sensing; Real samples




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website