Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   E. Mostafa,A.  Eissa,M.S.  Elsonbaty,A.  Attala,K.  A. Abdel Salam,R.  M. Hadad,G.  Abdelshakour,M.A    
Article title: Computer-Aided Design of Eco-Friendly Imprinted Polymer Decorated Sensors Augmented by Self-Validated Ensemble Modeling Designs for the Quantitation of Drotaverine Hydrochloride in Dosage Form and Human Plasma
Publication date: 2023
Journal : Journal of AOAC International
Volume: 106
Issue: (5)
Page numbers: (1361-1373)
DOI: 10.1093/jaoacint/qsad049

Abstract: Computationally designed molecular imprinted polymer (MIP) incorporation into electrochemical sensors has many advantages to the performance of the designed sensors. The innovative self-validated ensemble modeling (SVEM) approach is a smart machine learning-based (ML) technique that enables the design of more accurate predictive models using smaller data sets.The novel SVEM experimental design methodology is exploited here exclusively to optimize the composition of four eco-friendly PVC membranes augmented by a computationally designed magnetic molecularly imprinted polymer to quantitatively determine drotaverine hydrochloride (DVN) in its combined dosage form and human plasma. Furthermore, the application of hybrid computational simulations such as molecular dynamics and quantum mechanical calculations (MD/QM) is a time-saving and eco-friendly provider for the tailored design of the MIP particles.Here, for the first time, the predictive power of ML is assembled with computational simulations to develop four PVC-based sensors decorated by computationally designed MIP particles using four different experimental designs known as central composite, SVEM-LASSO, SVEM-FWD, and SVEM-PFWD. The pioneering AGREE approach further assessed the greenness of the analytical methods, proving their eco-friendliness.The proposed sensors showed decent Nernstian responses toward DVN in the range of 58.60–59.09 mV/decade with a linear quantitative range of 1 × 10−7 – 1 × 10−2 M and limits of detection in the range of 9.55 × 10−8 to 7.08 × 10−8 M. Moreover, the proposed sensors showed ultimate eco-friendliness and selectivity for their target in its combined dosage form and spiked human plasma.The proposed sensors were validated in accordance with International Union of Pure and Applied Chemistry (IUPAC) recommendations, proving their sensitivity and selectivity for drotaverine determination in dosage form and human plasma.This work presents the first ever application of both the innovative SVEM designs and MD/QM simulations in the optimization and fabrication of drotaverine-sensitive and selective MIP-decorated PVC sensors.
Template and target information:   drotaverine hydrochloride; DVN




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website