Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Laki,R.M.  Pourbasheer,E.  Eskandari,H.  Beheshti,A.    
Article title: Design and fabrication of a molecularly imprinted polymer-modified microfluidic chip for selective extraction and determination of bortezomib
Publication date: 2027
Journal : Journal of Chromatography A
Volume: 1791
Article number: 467646
DOI: 10.1016/j.chroma.2026.467646
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0021967326009684

Abstract: Development of novel and cost-effective techniques for the selective separation and measurement of target analytes in complex matrices appears to be an urgent need. In this study, a molecularly imprinted polymer-modified microfluidic chip was designed and fabricated for the selective extraction and determination of bortezomib based on HPLC. The chip was fabricated as a glass/polymethyl methacrylate/glass sandwich device in which the polymethyl methacrylate layer defined the microchannel geometry and the glass inner surfaces were modified with a bortezomib-imprinted polymer layer. Surface characterization by SEM confirmed the stepwise surface modification and the formation of a rough and porous MIP layer suitable for selective retention of the analyte. The extraction conditions were optimized using a one-at-a-time approach. Under optimized conditions, the method showed good linearity in the concentration range of 0.01–100 mg L-1 with a correlation coefficient of 0.9997. The limits of detection and quantification were 2.5 and 8.3 µg L-1, respectively, and the repeatability and reproducibility values ​​of the method were 6.7 and 15.5, respectively (n = 3). The method was successfully applied to spiked urine samples and commercial bortezomib injection samples, yielding recoveries of 96.51–100.14% and 102.74–104.57%, respectively, with RSD values ​​of <2.40%. These results demonstrate that the proposed MIP-modified microfluidic chip is a simple, selective, and efficient platform for bortezomib sample preparation prior to HPLC determination.
Template and target information:   bortezomib
Author-assigned keywords: Bortezomib; Molecularly imprinted polymer; Microfluidic chip; HPLC; Extraction




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website