Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Yang,Q.D.  Yi,J.F.  Zhao,S.  Pu,F.  Zhang,Y.L.  Gao,L.X.  Wang,H.B.  Yang,W.R.  Pang,P.F.    
Article title: Heterostructured CuO/g-C3N4 nanocomposite-based molecularly imprinted electrochemical sensor for the detection of microcystin-LR
Publication date: 2026
Journal : Analytical Methods
Volume: 18
Issue: (43)
Page numbers: (10168-10174)
DOI: 10.1039/d6ay01027j

Abstract: Microcystin-LR (MC-LR) is one of the most toxic liver-damaging toxins that can be produced during cyanobacteria blooms and poses a threat to human health, emphasizing the need for new detection methods. A molecularly imprinted electrochemical sensor was developed for the detection of MC-LR based on a copper oxide and graphitic carbon nitride (CuO/g-C3N4) nanocomposite. CuO/g-C3N4 nanocomposite is synthesized using an in situ growth method wherein the CuO nanoparticles are homogenously dispersed on g-C3N4 nanosheets, forming a CuO/g-C3N4 p–n heterojunction. This composite effectively facilitates the charge transfer process while significantly enhancing the detection signal intensity. A molecularly imprinted polymer (MIP) film was directly prepared on the surface of a CuO/g-C3N4 coated glassy carbon electrode via free-radical polymerization using MC-LR as a template along with suitable functional monomers. Following template removal, the resulting molecularly imprinted cavities within the MIP demonstrated high specificity for MC-LR recognition. The MIP-based electrochemical sensor exhibited an excellent linear response and high sensitivity for MC-LR detection over a broad concentration range of 0.2–300 ng mL−1, achieving a low limit of detection (LOD) of 0.08 ng mL−1 (calculated using 3σ/S). The sensor demonstrated excellent selectivity, reproducibility, and stability for the rapid and ultrasensitive detection of MC-LR, thereby providing a critical analytical capability for safeguarding environmental quality and public health.
Template and target information:   microcystin-LR; MC-LR




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website