Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Wang,W.  He,S.T.  Li,S.Z.  Liu,M.H.  Pan,Y.    
Article title: Enhanced sensitivity of SAW gas sensor coated molecularly imprinted polymer incorporating high frequency stability oscillator
Publication date: 2007
Journal : Sensors and Actuators B: Chemical
Volume: 125
Issue: (2)
Page numbers: (422-427)
DOI: 10.1016/j.snb.2007.02.037
Alternative URL: http://www.sciencedirect.com/science/article/B6THH-4N68NG7-6/2/190e8bf16ca1391d115719f03f1af3d9

Abstract: This paper presents a 300 MHz surface acoustic wave (SAW) gas sensor coated molecularly imprinted polymer incorporating a novel SAW oscillator with high frequency stability. A SAW delay line on ST-X quartz substrate with low insertion loss (less than 12 dB) and single mode selection capability was fabricated as the oscillator element. Electrode width control single phase unidirectional transducer (EWC/SPUDT) configuration and comb transducer were used to structure the SAW device to minimize the insertion loss and accomplish the single mode selection, respectively. Prior to fabrication, coupling of modes (COM) simulation was performed to predict device performance. The measured frequency response S12 showed a good agreement with simulated results. The effect of oscillator circuit system temperature shift upon frequency stability of the fabricated oscillator was studied in detail. Typical short-term frequency stability (1 h) of ~0.06 ppm (~20 Hz) for the fabricated 300 MHz SAW oscillator was observed in a laboratory environment with temperature control. The oscillator was successfully applied to gas sensor coated 10 nm molecularly imprinted polymer (MIP) as sensor material for dimethyl-methyl-phosphonate (DMMP), and the MIP was prepared using o-phenylenediamine (o-PD) as a functional monomer, Sarin acid as a molecular template and co-polymerized using cyclic voltammetry (CV). The sensitivity for DMMP concentrations detection in a range of 1-100 mg/m3 was evaluated as ~96 Hz/mg/m3, and the threshold detection limit was up to 0.5 mg/m3
Template and target information:   dimethyl-methyl-phosphonate; DMMP
Author-assigned keywords: EWC; SPUDT; Delay line; Frequency stability; gas sensor; Mode selection; SAW oscillator; sensitivity; MIP




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website