Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Ali,M.  Horikawa,S.  Venkatesh,S.  Saha,J.  Hong,J.W.  Byrne,M.E.    
Article title: Zero-order therapeutic release from imprinted hydrogel contact lenses within in vitro physiological ocular tear flow
Publication date: 2007
Journal : Journal of Controlled Release
Volume: 124
Issue: (3)
Page numbers: (154-162)
DOI: 10.1016/j.jconrel.2007.09.006
Alternative URL: http://www.sciencedirect.com/science/article/B6T3D-4PPW6VC-1/2/763eac6c2a126c6f44742ef5bb97a60e

Abstract: Zero-order or concentration independent release kinetics are highly desirable from drug delivery devices. In this paper we demonstrate experimentally, for the first time, zero-order release of a small molecular weight therapeutic, ketotifen fumarate (MW = 425), from molecularly imprinted hydrogels used as therapeutic contact lenses. We performed dynamic, in vitro drug release studies from imprinted hydrogel contact lenses within a novel microfluidic device that simulates the volumetric flow rates, tear volume and tear composition of the eye. Imprinted gels with multiple functional monomers and complexation points to the drug demonstrated a significantly delayed release of drug compared to less functionalized systems. There were no statistical differences in experimentally determined equilibrium swollen polymer volume fractions, which correlate with molecular weight between crosslinks and mesh size of the gel. Under infinite sink conditions, imprinted contact lenses demonstrated Fickian (concentration dependent) release kinetics with diffusion coefficients ranging from 4.04 × 10- 9 to 5.57 × 10- 10 cm2/s. The highest functionalized gel exhibited a diffusion coefficient averaging ten times smaller than less functionalized gels and released drug for over 5 days with 3 distinct rates of release. Under physiological volumetric flow rates, the release rate was constant for a duration of 3.5 days delivering a therapeutically relevant dosage and was fit to a power law model indicating zero-order release characteristics with n = 0.981 +/- 0.006 (r2 = 0.997). This work demonstrates the potential of micro/nanofluidic devices to determine physiological release rates and stresses the importance of matching local conditions to adequately characterize drug delivery devices. It also demonstrates the enormous potential for molecular imprinting to further tailor therapeutic release kinetics via the imprinting process
Template and target information:   ketotifen fumarate
Author-assigned keywords: biomimetic; controlled release; drug delivery; Microfluidics; molecular imprinting




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website