Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Anderson,R.A.  Ariffin,M.M.  Cormack,P.A.G.  Miller,E.I.    
Article title: Comparison of molecularly imprinted solid-phase extraction (MISPE) with classical solid-phase extraction (SPE) for the detection of benzodiazepines in post-mortem hair samples
Publication date: 2008
Journal : Forensic Science International
Volume: 174
Issue: (1)
Page numbers: (40-46)
DOI: 10.1016/j.forsciint.2007.03.002
Alternative URL: http://www.sciencedirect.com/science/article/B6T6W-4NKJ1F4-1/2/1ad2b98a2e9eeb619e159c04392fbd89

Abstract: This preliminary study compares the benzodiazepine results for 10 post-mortem scalp hair samples using a classical solid-phase extraction (SPE) and a molecularly imprinted solid-phase extraction (MISPE) system. The hair samples selected for testing were from drug-related deaths where a positive benzodiazepine blood result was obtained. Samples were decontaminated with 0.1% sodium dodecyl sulfate, distilled water and dichloromethane, incubated overnight in methanol/25% aqueous ammonium hydroxide (20:1), extracted by SPE or MISPE and subsequently analysed by liquid chromatography-tandem mass spectrometry (LC-MS-MS). Both extraction methods detected diazepam, nordiazepam, oxazepam, temazepam and nitrazepam in the samples. Diazepam was detected in a greater number of samples using MISPE due to both its lower limit of detection (LOD) and higher extraction recovery as a result of excellent molecular recognition of the template (diazepam) imparted by the imprinting process. The selective recognition of two diazepam analogues, nordiazepam and oxazepam, was demonstrated using MISPE since they were also detected in a greater number of samples. In contrast, another diazepam analogue, temazepam, was detected in a greater number of samples using SPE since the LOD using this extraction was lower than with MISPE. Nitrazepam was detected in one sample using both extraction methods. Overall the MISPE and SPE hair results were in good qualitative agreement. For the samples, where both extraction methods detected nordiazepam, temazepam and oxazepam, the concentrations were always higher for SPE. This is probably due to the MIP procedure producing extracts with fewer matrix interferences than the extracts produced using the classical SPE method. MISPE could be used as a complementary method to classical SPE for the analysis of benzodiazepine positive hair samples collected from chronic users
Template and target information:   benzodiazepines; diazepam; nordiazepam; oxazepam; temazepam; nitrazepam
Author-assigned keywords: Benzodiazepines; Hair; SPE; MISPE; LC-MS-MS




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website