Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Guo,L.Y.  Jiang,X.M.  Yang,C.L.  Zhang,H.X.    
Article title: Analysis of sulfamerazine in pond water and several fishes by high-performance liquid chromatography using molecularly imprinted solid-phase extraction
Publication date: 2008
Journal : Analytical and Bioanalytical Chemistry
Volume: 391
Issue: (6)
Page numbers: (2291-2298)
DOI: 10.1007/s00216-008-2131-8

Abstract: Abstract: The synthesis and evaluation of a molecularly imprinted polymer (MIP) used as a selective solid-phase extraction sorbent and coupled to high-performance liquid chromatography (HPLC) for the efficient determination of sulfamerazine (SMR) in pond water and three fishes are reported. The polymer was prepared using SMR as the template molecule, methacrylic acid as the functional monomer and ethylene glycol dimethacrylate as the crosslinking monomer in the presence of tetrahydrofuran as the solvent. The SMR-imprinted polymers and nonimprinted polymers were characterized by FT-IR and static adsorption experiments. The prepared SMR-imprinted material showed a high adsorption capacity, significant selectivity and good site accessibility. The maximum static adsorption capacities of the SMR-imprinted and nonimprinted materials for SMR were 108.8 and 79.6 mg g?1, respectively. The relative selectivity factor of this SMR-imprinted material was 1.6. Several parameters influencing the solid-phase extraction process were optimized. Finally, the SMR-imprinted polymers were used as the sorbent in solid-phase extraction to determine SMR in pond water and three fishes with satisfactory recovery. The average recoveries of the MIP-SPE method were 94.0% in ultrapure water and 95.8% in pond water. Relative standard deviations ranging from 0.3% to 5.2% in MIP were acquired. The results for the SMR concentrations in crucian, carp and wuchang fish were 66.0, 127.1 and 51.5 ng g?1, respectively. The RSDs (n=5) were 3.51%, 0.53% and 5.08%, respectively. The limit of detection (LOD) for SMR was 1 ng g?1 and the limit of quantitation (LOQ) was 3.5& ng g?1
Template and target information:   sulfamerazine; SMR
Author-assigned keywords: molecularly imprinted polymers (MIPs); Solid-phase extraction; Sulfamerazine (SMR); High-performance liquid chromatography (HPLC)




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website