Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Yang,T.  Li,Y.H.  Wei,S.  Li,Y.  Deng,A.P.    
Article title: Development of a selective molecularly imprinted polymer-based solid-phase extraction for indomethacin from water samples
Publication date: 2008
Journal : Analytical and Bioanalytical Chemistry
Volume: 391
Issue: (8)
Page numbers: (2905-2914)
DOI: 10.1007/s00216-008-2218-2

Abstract: Abstract: A selective molecularly imprinted solid-phase extraction (MISPE) for indomethacin (IDM) from water samples was developed. Using IDM as template molecule, acrylamide (AM) or methacrylic acid (MAA) as functional monomer, ethylene dimethacrylate (EDMA) as crosslinker, and bulk or suspension polymerization as the synthetic method, three molecularly imprinted polymers (MIPs) were synthesized and characterized with a rebinding experiment. It was found that the MIP of AM-EDMA produced by bulk polymerization showed the highest binding capacity for IDM, and so it was chosen for subsequent experiments, such as those testing the selectivity and recognition binding sites. Scatchard analysis revealed that at least two kinds of binding sites formed in the MIP, with the dissociation constants of 7.8 ?mol L?1 and 127.2 ?mol L?1, respectively. Besides IDM, three structurally related compounds ù acemetacin, oxaprozin and ibuprofen ù were employed for selectivity tests. It was observed that the MIP exhibited the highest selective rebinding to IDM. Accordingly, the MIP was used as a solid-phase extraction sorbent for the extraction and enrichment of IDM in water samples. The extraction conditions of the MISPE column for IDM were optimized to be: chloroform or water as loading solvent, chloroform with 20% acetonitrile as washing solution, and methanol as eluting solvent. Water samples with or without spiking were extracted by the MISPE column and analyzed by HPLC. No detectable IDM was observed in tap water and the content of IDM in a river water sample was found to be 1.8 ng mL?1. The extraction efficiencies of the MISPE column for IDM in spiked tap and river water were acceptable (87.2% and 83.5%, respectively), demonstrating the feasibility of the prepared MIP for IDM extraction
Template and target information:   indomethacin; IDM
Author-assigned keywords: molecularly imprinted polymer (MIP); Indomethacin (IDM); Solid-Phase Extraction (SPE); Water sample




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website