Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Zanganeh,A.R.  Amini,M.K.    
Article title: Polypyrrole-modified electrodes with induced recognition sites for potentiometric and voltammetric detection of copper(II) ion
Publication date: 2008
Journal : Sensors and Actuators B: Chemical
Volume: 135
Issue: (1)
Page numbers: (358-365)
DOI: 10.1016/j.snb.2008.09.005
Alternative URL: http://www.sciencedirect.com/science/article/B6THH-4TDK6SG-3/2/8a10dd85cad49e1e1605ce4575c6521d

Abstract: Polypyrrole modified electrodes prepared by electropolymerization of pyrrole in the presence of an anionic complexing ligand, Eriochrome Blue-black B, were templated with respect to copper ions and used for potentiometric and voltammetric detection of this ion. The templating process improved the analytical response characteristics of the electrodes, particularly their selectivity, with respect to copper ion. The improvement depends on both the incorporated ligand and the templating process, with the latter being more important. The potentiometric response of the electrode was linear within the Cu2+ concentration range 5á+á10-8 to 1á+á10-2áM with a near-Nernstian slope of 28.4ámV and a detection limit of 1á+á10-8áM. The templated electrode showed good potentiometric selectivity for copper ion with respect to several metal ions, including mercury and silver ions. The electrodes were also used for preconcentration differential pulse anodic stripping voltammetric measurement of copper ion. Experimental results exhibited that the stripping peak currents for the incorporated copper species were dependent on the metal ion concentration in the range 3.2á+á10-9 to 1á+á10-4áM. Several transition metal ions did not show significant interference in the voltammetric determination of copper ion, however, mercury and silver ions caused significant interferences
Template and target information:   copper ions; Cu2+
Author-assigned keywords: polypyrrole; electropolymerization; Copper-selective electrode; voltammetry; Eriochrome Blue-black B




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website