Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Zhang,S.W.  Xing,J.  Cai,L.S.  Wu,C.Y.    
Article title: Molecularly imprinted monolith in-tube solid-phase microextraction coupled with HPLC/UV detection for determination of 8-hydroxy-2'-deoxyguanosine in urine
Publication date: 2009
Journal : Analytical and Bioanalytical Chemistry
Volume: 395
Issue: (2)
Page numbers: (479-487)
DOI: 10.1007/s00216-009-2964-9

Abstract: Abstract: Urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) has been widely used as a biomarker of oxidative DNA damage. Measurements of 8-OHdG in urinary samples are challenging owing to the low level of 8-OHdG and the complex matrix. In this study, a novel molecularly imprinted polymer (MIP) monolithic column was synthesized with guanosine as a dummy template which was used as the medium for in-tube solid-phase microextraction (SPME). In-tube SPME coupled with HPLC/UV detection for extraction and determination of urinary 8-OHdG was developed. The synthesized MIP monolithic column exhibited high extraction efficiency owing to its greater phase ratio with convective mass transfer and inherent selectivity. The enrichment factor for 8-OHdG was found to be 76 and the limits of detection and quantification of the method for urinary samples were 3.2 nmol/L (signal-to-noise ratio 3) and 11 nmol/L (signal-to-noise ratio 10), respectively. The MIP's selectivity also made the sample preparation procedure and chromatographic separation much easier. The linear range of the proposed method was from 0.010 to 5.30 ?mol/L (r?=?0.9997), with a relative standard deviation of 1.1–6.8%, and the recovery for spiked urine samples was 84?±?3%. The newly developed method was successfully applied to determine urinary samples of healthy volunteers, coking plant workers, and cancer patients. The 8-OHdG level in cancer patients was significantly higher than that in healthy people
Template and target information:   8-hydroxy-2'-deoxyguanosine; 8-OHdG
Author-assigned keywords: Molecularly imprinted monolith; in-tube solid-phase microextraction; 8-Hydroxy-2'-deoxyguanosine; urine




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website