Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Pietrzyk,A.  Suriyanarayanan,S.  Kutner,W.  Chitta,R.  Zandler,M.E.  D'Souza,F.    
Article title: Molecularly imprinted polymer (MIP) based piezoelectric microgravimetry chemosensor for selective determination of adenine
Publication date: 2010
Journal : Biosensors and Bioelectronics
Volume: 25
Issue: (11)
Page numbers: (2522-2529)
DOI: 10.1016/j.bios.2010.04.015
Alternative URL: http://www.sciencedirect.com/science/article/B6TFC-4YWYYRN-2/2/6d262b4d4f86911b763f2127a52d2cc3

Abstract: An adenine-templated molecularly imprinted polymer (MIP) film, deposited on a poly(bithiophene) barrier film, served as the recognition element of a piezomicrogravimetric (acoustic) chemosensor. A 10áMHz AT-cut shear-thickness-mode bulk-acoustic-wave quartz crystal resonator with Pt film electrodes was used as the signal transducer. Adenine electrooxidation was prevented by the barrier film. The MIP film was deposited by electrochemical co-polymerization of two functional monomers of bis(bithiophene) derivatives, bearing either the 18-crown-6 or dioxaborinane substituent, in the presence of the adenine template. A strong base solution was then used to extract the template. Completeness of the template removal was substantiated by the UV-vis, XPS, DPV, and EIS measurements. The chemosensor performance was evaluated with the piezoelectric microgravimetry detection at QCM under FIA conditions using a carrier acetonitrile-water (1:1, v:v) mixed solvent solution. The linear dynamic concentration range extended from at least 0.1 to 1mM for the 35 μL/min flow rate, and 100 μL volume of the injected adenine solution. The chemosensor selectivity allowed for discrimination of the adenine analyte from structurally and functionally related interferants, such as 2-aminopurine, guanine, and ascorbic acid. The determined from the FIA kinetic studies stability constant of the MIP-adenine complex, (18 ± 2.4) × 10 4 M-1, was much higher than that of the MIP-(2-aminopurine), (650 ± 90) M-1, MIP-guanine, (122 ± 11) M-1, and MIP-(ascorbic acid), (92 ± 10) M-1, complexes. The concentration limit of detection was as low as 5 nM adenine for the 35 μL/min flow rate, and 1 mL volume of the injected sample solution
Template and target information:   adenine
Author-assigned keywords: Molecularly imprinted polymers; Adenine piezoelectric chemosensor; Adenine acoustic chemosensor; Bis(bithiophene) electropolymerization; Barrier layer; Poly(bithiophene)




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website