Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Chang,J.  Zhu,J.  Di,Y.  Zhang,L.  Cui,W.  Hao,H.  Yu,Z.    
Article title: Application of molecularly imprinted solid-phase extraction for separating and assaying amphetamines in blood samples
Publication date: 2011
Journal : Chinese Journal of Forensic Medicine
Volume: 26
Issue: (1)
Page numbers: (22-25)
Alternative URL: http://en.cnki.com.cn/Article_en/CJFDTotal-FUAN201101010.htm

Abstract: Objecive A method for extraction of amphetamines in blood samples using molecularly imprinted solid phase extraction and gas chromatography -mass spectrometry (GC/MS). Methods Human blood samples were spiked with amphetamine, methamphetamine, MDA and MDMA, and diluted with 4:1 (v/v) with 10mmol/L ammonium acetate buffer (pH8.0); activating the MIP column with 1mL methanol and 1mL 10mmol/L ammonium acetate(pH8.0); Washing the impurities using 21mL water, 1mL 60/40 MeCN/water and 1mL 1% HAc in MeCN; Elute the amphetamine drugs with 21mL 1% formic acid in methanol, then evaporate under nitrogen to dryness and reconstitute with 100 μL methanol prior to GC/MS analysis. Results The recoveries obtained with this method for amphetamine drugs are more than 90%. The linear range was 20 ~ 5000ng/mL with correlation coefficients between 0.995 7 and 0.998 9. The limits of detection were 20ng/mL for amphetamine (AM), 16ng/mL methamphetamine (MA), 30ng/mL methylenedioxyamphetamine (MDA) and methylened ioxy methamp hetamine (MDMA), The limits of quantitative were 10ng/mL for AM, 8ng/mL for methamphetamine (MAM), 15ng/mL for MDA and MDMA. Conclusion Recoveries are higher, impurities were less. The method could be applied for simultaneous determination of trace amphetamines in biological specimens
Template and target information:   amphetamine; AM; methamphetamine; MAM; methylenedioxyamphetamine; MDA; MDMA; methylenedioxymethamphetamine
Author-assigned keywords: Amphetamines; Forensic toxicology analysis; GC; MS; GC; NPD; molecularly imprinted solid phase extraction




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website