Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Lian,W.J.  Huang,J.D.  Yu,J.H.  Zhang,X.M.  Lin,Q.  He,X.R.  Xing,X.R.  Liu,S.    
Article title: A molecularly imprinted sensor based on β-cyclodextrin incorporated multiwalled carbon nanotube and gold nanoparticles-polyamide amine dendrimer nanocomposites combining with water-soluble chitosan derivative for the detection of chlortetracycline
Publication date: 2012
Journal : Food Control
Volume: 26
Issue: (2)
Page numbers: (620-627)
DOI: 10.1016/j.foodcont.2012.02.023
Alternative URL: http://www.sciencedirect.com/science/article/pii/S0956713512001053

Abstract: We developed a molecularly imprinted electrochemical sensor based on gold electrode decorated by β-cyclodextrin (CD) incorporated multiwalled carbon nanotube, gold nanoparticles-polyamide amine dendrimer nanocomposites (Au-PAMAM) and chitosan derivative (CSDT) for selective and convenient determination of chlortetracycline (CTC). The electrochemical sensor was fabricated by stepwise modification of cyclodextrin-multiwalled carbon nanotube composites (CD-MWCNTs) and Au-PAMAM onto the gold electrode. The layer of MIPs was the outer layer of the electrochemical sensor. In this article, CSDT acted as functional monomer, and CTC as the template molecule. Cyclic voltammetry (CV) and amperometry were used to characterize the electrochemical behavior of the developed sensor. The linear range of the molecularly imprinted sensor was from 9.00 × 10-8 to 5.00 × 10-5 mol/L (from 0.0464 mg/kg to 25.767 mg/kg), with the limit of detection (LOD) of 4.954 × 10-8 mol/L (0.0255 mg/kg, S/N = 3). The developed sensor showed high selectivity and excellent stability toward CTC. The results from real sample analysis confirmed the applicability of the sensor to quantitative analysis
Template and target information:   chlortetracycline; CTC
Author-assigned keywords: Molecularly imprinted polymers; chitosan derivative; β-cyclodextrin-multiwalled carbon nanotube composites; Gold nanoparticles-polyamide amine dendrimer nanocomposites; Chlortetracycline detection




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website