Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Queiros,R.B.  Noronha,J.P.  Marques,P.V.S.  Fernandes,J.S.  Sales,M.G.    
Article title: Determination of Microcystin-LR in waters in the subnanomolar range by sol-gel imprinted polymers on solid contact electrodes
Publication date: 2012
Journal : Analyst
Volume: 137
Issue: (10)
Page numbers: (2437-2444)
DOI: 10.1039/C2AN35141B

Abstract: The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol-Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol-Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol-gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 × 10-10 M, corresponding to 0.75 μg L-1. It showed linear responses in the range of 7.7 × 10-10 to 1.9 × 10-9 M of MC-LR (corresponding to 0.77-2.00 μg L-1), thus including the limiting value for MC-LR in waters (1.0 μg L-1). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl-) showed limited interference while aluminium (Al3+), ammonium (NH4+), magnesium (Mg2+), manganese (Mn2+), sodium (Na+), and sulfate (SO42-) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods
Template and target information:   microcystin-LR; MC-LR




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website