Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Javanbakht,M.  Moein,M.M.  Akbari-Adergani,B.    
Article title: On-line clean-up and determination of tramadol in human plasma and urine samples using molecularly imprinted monolithic column coupling with HPLC
Publication date: 2012
Journal : Journal of Chromatography B
Volume: 911
Page numbers: (49-54)
DOI: 10.1016/j.jchromb.2012.10.019
Alternative URL: http://www.sciencedirect.com/science/article/pii/S1570023212006034

Abstract: The applicability of an on-line solid phase extraction method using molecularly imprinted monolithic column was developed for the assay of tramadol (TRD) in urine and plasma samples. The monolithic column was prepared by using TRD as the template, methacrylic acid (MAA) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker and chloroform as the porogen with in situ molecular imprinting polymerization technique. Various parameters affecting the extraction efficiency of the monolithic column were evaluated. Chromatographic analysis of TRD after on-line clean-up of samples was performed by reversed-phase HPLC on an ACE column with ultraviolet detection at 218 nm. The present work was successfully applied for automated simple analysis of TRD in urine and plasma samples with high recoveries between 90.5 - 93.1% and 93.3 - 96.0%, respectively. The results revealed that in concentration up to 500 ng/mL of dextromethorphan (DEX), timolol (TMO) and O-desmethyltramadol (M1), the recoveries were not reduced more than 4.3% and 4.0% for plasma and urine samples, respectively. The limit of detection (S/N = 3) and limit of quantification (S/N = 10) for TRD in urine samples were 0.03 ng/mL and 0.10 ng/mL, and in plasma samples were 0.3 and 1.0 ng/mL, respectively. Inter-column precision of the assays (n = 3) for urine and plasma samples at the 100 ng/mL TRD level were 4.0% and 4.2%, respectively
Template and target information:   tramadol; TRD
Author-assigned keywords: molecularly imprinted polymer; Tramadol; human plasma; monolithic column; Sample clean-up




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website