Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Alizadeh,T.  Fard,L.A.    
Article title: Synthesis of Cu2+-mediated nano-sized salbutamol-imprinted polymer and its use for indirect recognition of ultra-trace levels of salbutamol
Publication date: 2013
Journal : Analytica Chimica Acta
Volume: 769
Page numbers: (100-107)
DOI: 10.1016/j.aca.2013.01.032
Alternative URL: http://www.sciencedirect.com/science/article/pii/S0003267013001803

Abstract: Cu2+-mediated salbutamol-imprinted polymer nanoparticles, synthesized by precipitation polymerization, were mixed with graphite powder and n-eicosane in order to fabricate a modified carbon paste electrode. This electrode was then applied for indirect differential pulse voltammetry determination of salbutamol. In the presence of Cu2+ ions, the formed Cu2+ - salbutamol complex was adsorbed in to the pre-designed cavities of the MIP particles, situated on the electrode surface. Since the electrochemical signal of salbutamol was intrinsically small, the oxidation peak of the participant Cu2+, after reduction step, was recorded and used as an indication of salbutamol amount, adsorbed in the electrode. Different variables influencing the sensor performance were studied and the best conditions were chosen for the determination purpose. Correlation between the sensor response to salbutamol and its concentration was linear in the range of 1.0 × 10-9 - 5.5 × 10-8 M. Detection limit was calculated equal to 6.0 × 10-10 M (S/N). Five replicated determination of salbutamol (1 × 10-8 M) resulted in standard error of 3.28%, meaning a satisfactory precision of the determination method. The prepared sensor was applied for real sample analysis. In order to minimize the interference effect, the synthesized polymer was successfully used as a solid phase sorbent for salbutamol extraction, before analysis of real samples by the developed sensor
Template and target information:   salbutamol
Author-assigned keywords: salbutamol; Nano-sized imprinted polymer; Cu2+; carbon paste electrode




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website