Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Prasad,B.B.  Jauhari,D.  Tiwari,M.P.    
Article title: A dual-template imprinted polymer-modified carbon ceramic electrode for ultra trace simultaneous analysis of ascorbic acid and dopamine
Publication date: 2013
Journal : Biosensors and Bioelectronics
Volume: 50
Page numbers: (19-27)
DOI: 10.1016/j.bios.2013.05.062
Alternative URL: http://www.sciencedirect.com/science/article/pii/S0956566313003965

Abstract: A dual-template imprinted polymer film containing dispersed multiwalled carbon nanotubes was exploited in the fabrication of a typical, reproducible, and rugged carbon ceramic electrode, adopting "surface grafting from" approach for the growth of a nanometer thin coating on its surface. For this, chloro groups were first introduced at the exterior surface of silica-carbon composite electrode through sol-gel modification using (3-chloropropyl)-trimethoxysilane, followed by an iniferter (sodium diethyl dithiocarbamate) initiated photopolymerization of functional monomer (2,4,6-trisacrylamido-1,3,5-triazine), mixed templates (ascorbic acid and dopamine), and cross-linker (ethylene glycol dimethacrylate), in the presence of multiwalled carbon nanotubes. The modified sensor was validated for the simultaneous analysis of ascorbic acid and dopamine in aqueous, blood serum, cerebrospinal fluid, and pharmaceutical samples, using differential pulse anodic stripping voltammetric technique. The oxidation peak potentials for both analytes were found to be well apart approximately by 300 mV, which was large enough to allow selective and sensitive analysis of one in the presence of other, without any cross reactivity, interferences and false-positives. The detection limits realized by the proposed sensor, under optimized conditions, were found to be as low as 2.24 ng mL-1 for ascorbic acid and 0.21 ng mL-1 for dopamine (S/N=3). Such stringent limits could be considered suitable for the primitive diagnosis of several chronic diseases, in clinical settings
Template and target information:   ascorbic acid; vitamin C; dopamine
Author-assigned keywords: Dual template imprinted polymer film; Carbon ceramic electrode; ascorbic acid; dopamine; Differential pulse anodic stripping voltammetry; Simultaneous ultra trace analysis




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website