Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Ferey,L.  Delaunay,N.  Rutledge,D.N.  Huertas,A.  Raoul,Y.  Gareil,P.  Vial,J.    
Article title: Use of response surface methodology to optimize the simultaneous separation of eight polycyclic aromatic hydrocarbons by capillary zone electrophoresis with laser-induced fluorescence detection
Publication date: 2013
Journal : Journal of Chromatography A
Volume: 1302
Page numbers: (181-190)
DOI: 10.1016/j.chroma.2013.06.027
Alternative URL: http://www.sciencedirect.com/science/article/pii/S0021967313009229

Abstract: Polycyclic aromatic hydrocarbons (PAHs) are among the most targeted contaminants by international regulatory institutions. There is thus a need for fast, selective and sensitive analytical methods to quantify these compounds at trace levels in complex samples. This article focuses on the optimization by means of an experimental design of a CE method with laser-induced fluorescence detection for the fast simultaneous separation of 8 heavy PAHs among food and environmental priority pollutants: benzo(a)pyrene, benzo(a)anthracene, chrysene, benzo(b)fluoranthene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, benzo(k)fluoranthene, and benzo(ghi)perylene. In this method, capillary zone electrophoresis with a mixture of an anionic sulfobutyl ether-β-cyclodextrin (SBE-β-CD) and a neutral methyl-β-cyclodextrin (Me-β-CD) was used to separate PAHs, on the basis of their differential distribution between the two CDs. First, the factors most affecting PAH electrophoretic behavior were identified: SBE-β-CD and Me-β-CD concentrations and percentage of methanol added to the background electrolyte. Then, a response surface strategy using a central composite design was carried out to model the effects of the selected factors on the normalized migration times. To optimize the separation, desirability functions were applied on modeled responses: normalized migration time differences between peak end and peak start of two consecutive peaks, and overall analysis time. From the model, predicted optimum conditions were experimentally validated and full resolution of all 8 PAHs was achieved in less than 7 min using a borate buffer composed of 5.3 mM SBE-β-CD, 21.5 mM Me-β-CD and 10.3% MeOH. This CE separation method was successfully applied to real edible oil analysis
Template and target information:   benzo(a)pyrene; benzo(a)anthracene; chrysene; benzo(b)fluoranthene; dibenzo(a,h)anthracene; indeno(1,2,3-cd)pyrene; benzo(k)fluoranthene; benzo(ghi)perylene; commercial MIP
Author-assigned keywords: design of experiments; capillary zone electrophoresis; cyclodextrins; polycyclic aromatic hydrocarbons; fluorescence detection; Edible oil




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website