Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Tian,L.M.  Liu,K.K.  Morrissey,J.J.  Gandra,N.  Kharasch,E.D.  Singamaneni,S.    
Article title: Gold nanocages with built-in artificial antibodies for label-free plasmonic biosensing
Publication date: 2014
Journal : Journal of Materials Chemistry B
Volume: 2
Issue: (2)
Page numbers: (167-170)
DOI: 10.1039/C3TB21551B

Abstract: We demonstrate that gold nanocages (AuNCs) with built-in artificial antibodies enable the detection of kidney injury biomarker from synthetic urine down to a concentration of 25 ng ml-1. Molecularly imprinted AuNCs exhibit excellent selectivity against numerous interfering urinary proteins and remarkable stability over a wide range of pH and specific gravity
Template and target information:   protein; kidney injury biomarker; neutrophil gelatinase-associated lipocalin; NGAL




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website