MIPs logo MIPdatabase      MIP2024 Conference banner, website is now open, register on site for important updates   
Reference type: Journal
Authors: Costa R, Costa J, Moreira P, Brandão ATSC, Mafra I, Silva AF, Pereira CM
Article Title: Molecularly imprinted polymer as a synthetic antibody for the biorecognition of hazelnut Cor a 14-allergen.
Publication date: 2021
Journal: Analytica Chimica Acta
Article Number: 339310.
DOI: 10.1016/j.aca.2021.339310
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0003267021011363

Abstract: Artificial receptors that mimic their natural biological counterparts have several advantages, such as lower production costs and increased shelf-life stability/versatility, while overcoming the ethical issues related to raising antibodies in animals. In this work, the proposed tailor-made molecularly imprinted polymer (MIP)-allergen receptors aimed at substituting or even transcending the performance of biological antibodies. For this purpose, a MIP was proposed as an artificial antibody for the recognition of hazelnut Cor a 14-allergen. The target protein was grafted onto the conducting polypyrrole receptor film using gold screen-printed electrodes (Au-SPE). The electrochemical assessment presented a linear response for the dynamic range of 100 fg mL-1 - 1 μg mL-1 and a LOD of 24.5 fg mL-1, as determined by square wave voltammetry from the calibration curves prepared with standards diluted in phosphate buffer. Surface plasmon resonance (SPR) was used as a secondary transducer to evaluate the performance of the Cor a 14-MIP sensor, enabling a linear dynamic range of 100 fg mL-1- 0.1 μg mL-1 and a LOD of 18.1 fg mL-1. The selectivity of the tailored-made Cor a 14-MIP was tested against potentially cross-reactive plant/animal species based on the rebinding affinity (Freundlich isotherm-KF) of homologues/similar proteins, being further compared with custom-made polyclonal anti-Cor a 14 IgG immunosensor. Results evidenced that the MIP mimics the biorecognition of biological antibodies, presenting higher selectivity (only minor cross-reactivity towards walnut and Brazil nut 2S albumins) than the Cor a 14/anti-Cor a 14 IgG immunosensor. The application of electrochemical Cor a 14-MIP sensor to model mixtures of hazelnut in pasta enabled quantifying hazelnut down to 1 mg kg-1 (corresponding to 0.16 mg kg-1 of hazelnut protein in the matrix). To the best of our knowledge, Cor a 14-MIP is the first sensor based on an artificial/synthetic biorecognition platform for the specific detection of hazelnut allergens, while presenting high-performance parameters with demonstrated application in food safety management
Author keywords: Hazelnut Cor a 14 allergen, Molecularly imprinted polymer (MIP), Food allergen detection, Cross-reactivity assessment, Polyclonal anti-Cor a 14 IgG (rabbit), Model foods


  Template of Doom spoof movie poster customisable greetings card  Chemistry peptide mug  Chemists are fun customisable shirt






 

Join the Society for Molecular Imprinting
Logo of the Society for Molecular Imprinting

New items RSS feed
new items RSS feed  View latest updates

Sign-up for e-mail updates:
Choose between receiving an occasional newsletter or more frequent e-mail alerts.
Click here to go to the sign-up page.


Is your name elemental or peptidic? Enter your name and find out by clicking either of the buttons below!
Other products you may like:
view listings for MIP books on eBay:



Mickey Mouse 90th Anniversary banner