Abstract: A glassy carbon electrode (GCE) was modified with magnetic molecularly imprinted polymers (mMIPs) using catechin as a template, reduced graphene oxide (rGO), and zeolitic imidazolate frameworks-8 (ZIF-8) for the sensitive detection of catechin (mMIPs/rGO-ZIF-8/GCE). The prepared rGO, ZIF-8, and mMIPs exhibited typical structures and properties determined by various characterizations. The mMIPs showed good selectivity for catechin among several structural analogs. The mMIPs/rGO-ZIF-8/GCE showed a higher maximum peak current for catechin than that of a single component modified GCE. After the optimization of the material ratio, coating amounts, pH, and scan rate, the mMIPs/rGO-ZIF-8/GCE exhibited good selectivity, good linearity, and a low detection limit (LOD) for catechin. The linear range was 0.01 nmol/L-10 μmol/L and the LOD was 0.003 nmol/L (S/N = 3). The relative standard deviations for reproducibility and stability tests (n = 6) were 5.2% and 6.1%, respectively. A recovery between 99.1 and 101.3% was obtained in the detection of catechin in spiked samples. Based on these findings, the proposed mMIPs/rGO-ZIF-8/GCE could be developed further, and future research could be conducted on alternate fabrication strategies and methods to create more portable and practical electrochemical sensors
Template and target information: catechin
Author keywords: Catechin, electrochemical detection, magnetic nanoparticles, molecularly imprinted polymer, Reduced graphene oxide, Zeolitic imidazolate frameworks