MIPs logo MIPdatabase      MIP2024 Conference banner, website is now open, register on site for important updates   
Custom Search
Reference type: Journal
Authors: Syu MJ, Chiu TC, Lai CY, Chang YS
Article Title: Amperometric detection of bilirubin from a micro-sensing electrode with a synthetic bilirubin imprinted poly(MAA-co-EGDMA) film.
Publication date: 2006
Journal: Biosensors and Bioelectronics
Volume: 22
Issue: (4)
Page numbers: 550-557.
DOI: 10.1016/j.bios.2006.07.035
Alternative URL: http://www.sciencedirect.com/science/article/B6TFC-4KV3XPC-2/2/427ecce06daecc087c6130635cb3714a

Abstract: Poly(methacrylic acid-co-ethyl glycol dimethylacrylate) (poly(MAA-co-EGDMA)) imprinted with α-bilirubin was shown to be able to bind α-bilirubin in our previous work. In this work, the corresponding imprinted polymer thin film was synthesized onto a thiol treated Au electrode by surface grafting polymerization. Bilirubin was able to be detected by an Au electrode, however, the electrode was not be able to discriminate bilirubin from the other matrix components if clinical samples were used. Therefore, the imprinted material was introduced so that the modified Au electrode could specifically detect bilirubin. Optimal potential was found to be 0.55 V and this was set for the rest of experiments. The imprinting factor of 3.16 was confirmed by comparing the signals from the MIP-Au and the NIP (non-imprinted polymer)-Au electrode. Calibration of the bilirubin concentration with respect to the current by the MIP-Au electrode was made within the range of 5 mg/dl and a detection sensitivity of 0.644 μA/mg/dl (2.58 μA/cm2/mg/dl) was obtained. Furthermore, a linear correlation of the bilirubin concentration within 1.0 mg/dl versus detection current was also achieved. Bilirubin was further detected by the MIP-Au electrode in the presence of fetal bovine serum (FBS). Repeated detection of bilirubin with at least three detection batches was performed and the reproducibility of the same piece of MIP-Au electrode was confirmed. The result was compared to those obtained from the serum and the solvent solution. The results indicated the feasibility of using the bilirubin imprinted poly(MAA-co-EGDMA) film as a sensing electrode for the clinical detection of bilirubin in serum
Template and target information: α-bilirubin, bilirubin
Author keywords: Bilirubin, molecularly imprinted polymer, MIP-Au electrode, binding specificity, Reproducibility, serum


  SMI logo mouse mat  Periodic table Perfect shirt  Lab Chick script shirt






 

Join the Society for Molecular Imprinting
Logo of the Society for Molecular Imprinting

New items RSS feed
new items RSS feed  View latest updates

Sign-up for e-mail updates:
Choose between receiving an occasional newsletter or more frequent e-mail alerts.
Click here to go to the sign-up page.


Is your name elemental or peptidic? Enter your name and find out by clicking either of the buttons below!
Other products you may like:
view listings for MIP books on eBay:



Mickey Mouse 90th Anniversary banner