MIPs logo MIPdatabase      MIP2024 Conference banner, website is now open, register on site for important updates   
Custom Search
Reference type: Journal
Authors: Wang W, He ST, Li SZ, Liu MH, Pan Y
Article Title: Enhanced sensitivity of SAW gas sensor coated molecularly imprinted polymer incorporating high frequency stability oscillator.
Publication date: 2007
Journal: Sensors and Actuators B: Chemical
Volume: 125
Issue: (2)
Page numbers: 422-427.
DOI: 10.1016/j.snb.2007.02.037
Alternative URL: http://www.sciencedirect.com/science/article/B6THH-4N68NG7-6/2/190e8bf16ca1391d115719f03f1af3d9

Abstract: This paper presents a 300 MHz surface acoustic wave (SAW) gas sensor coated molecularly imprinted polymer incorporating a novel SAW oscillator with high frequency stability. A SAW delay line on ST-X quartz substrate with low insertion loss (less than 12 dB) and single mode selection capability was fabricated as the oscillator element. Electrode width control single phase unidirectional transducer (EWC/SPUDT) configuration and comb transducer were used to structure the SAW device to minimize the insertion loss and accomplish the single mode selection, respectively. Prior to fabrication, coupling of modes (COM) simulation was performed to predict device performance. The measured frequency response S12 showed a good agreement with simulated results. The effect of oscillator circuit system temperature shift upon frequency stability of the fabricated oscillator was studied in detail. Typical short-term frequency stability (1 h) of ~0.06 ppm (~20 Hz) for the fabricated 300 MHz SAW oscillator was observed in a laboratory environment with temperature control. The oscillator was successfully applied to gas sensor coated 10 nm molecularly imprinted polymer (MIP) as sensor material for dimethyl-methyl-phosphonate (DMMP), and the MIP was prepared using o-phenylenediamine (o-PD) as a functional monomer, Sarin acid as a molecular template and co-polymerized using cyclic voltammetry (CV). The sensitivity for DMMP concentrations detection in a range of 1-100 mg/m3 was evaluated as ~96 Hz/mg/m3, and the threshold detection limit was up to 0.5 mg/m3
Template and target information: dimethyl-methyl-phosphonate, DMMP
Author keywords: EWC, SPUDT, Delay line, Frequency stability, gas sensor, Mode selection, SAW oscillator, sensitivity, MIP


  SMI logo cufflinks  Father Periodic table shirt  Lab Chick script shirt






 

Join the Society for Molecular Imprinting
Logo of the Society for Molecular Imprinting

New items RSS feed
new items RSS feed  View latest updates

Sign-up for e-mail updates:
Choose between receiving an occasional newsletter or more frequent e-mail alerts.
Click here to go to the sign-up page.


Is your name elemental or peptidic? Enter your name and find out by clicking either of the buttons below!
Other products you may like:
view listings for MIP books on eBay:



Mickey Mouse 90th Anniversary banner