Abstract: A simple, environmental friendly and selective sample preparation technique employing porous membrane protected micro-solid phase extraction (μ-SPE) loaded with molecularly imprinted polymer (MIP) for the determination of ochratoxin A (OTA) is described. After the extraction, the analyte was desorbed using ultrasonication and was analyzed using high performance liquid chromatography. Under the optimized conditions, the detection limits of OTA for coffee, grape juice and urine were 0.06 ng g-1, 0.02 and 0.02 ng mL-1, respectively while the quantification limits were 0.19 ng g-1, 0.06 and 0.08 ng mL-1, respectively. The recoveries of OTA from coffee spiked at 1, 25 and 50 ng g-1, grape juice and urine samples at 1, 25 and 50 ng mL-1 ranged from 90.6 to 101.5%. The proposed method was applied to thirty-eight samples of coffee, grape juice and urine and the presence of OTA was found in eighteen samples. The levels found, however, were all below the legal limits
Template and target information: ochratoxin A, OTA
Author keywords: ochratoxin A, molecularly imprinted polymer, Micro-solid phase extraction, high performance liquid chromatography, Coffee